Intelligent operation system; Easy operation with visual and audio alarms; Multi-purpose service/maintenance interface; Profiling: sodium concentration and UF curve;
Main performance of this device:
1. Self-checking function; 2. Carbonate dialysis; 3. Double needle dialysis; 4. Liquid level detector; 5. Bubble detector; 6. Blood leakage detector; 7. Temperature and electric conductivity monitoring; 8. Arterial pressure, venous pressure and transmembrane pressure monitoring; 9. Rolling blood pump; 10. Heparin pump; 11. Dehydration amount controlled by capacity; 12. Automatic disinfection cleaning program; 13. Stand-by power of blood pump in case of power failure; 14. Information display function of display screen.
PS:This device is designed and manufactured in strict accordance with the Requirements of national laws and regulations. The reference standards of design and manufacture are following: GB9706.1-2007; GB9706.2-2003; and YY0054-2003.
Techincal Parameter
Size &Weight:
Size: 380mmx400x1380mm (L*W*H);
Area: 500*520mm;
Weight: 80KG;
Power supply:
AC220V, 50Hz/60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes
Working Condition:
Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature: 5℃~30℃
Working environment temperature: 10℃~30℃ at relative humidity ≦70%
UF rate:
Flow range: 0ml/h~4000ml/h
Resolution ratio: 1ml
Precision: ±30ml/h
Blood pump &Spare pump:
Blood pump flow range: 30ml/min~600ml/min (diameter: 8mm or 6mm)
Spare pump flow range: 30ml/min~600ml/min (diameter 8mm or 6mm)
Resolution ratio: 0.1ml
Precision: ±10ml or 10% of reading
Heparin pump:
Syringe size: 20, 30, 50ml
Flow range: 0ml/h~10ml/h
Resolution ratio: 0.1ml
Precision: ±5%
Monitoring system &Alarm setup:
Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg TMP: -180mmHg ~ +600mmHg, ±20mmHg Dialysate temperature: preset range 34.0℃~39.0℃ Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate. Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow Conductivity: Acoustic-optic
Disinfection/Sanitize:
1. Hot disinfection: Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min; 2. Chemical disinfection: Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min; 3. Chemical disinfection with heat: Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min; 4. Rinse: Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;
Packing & Delivery
Storage Environment: Storage temperature should be between 5℃~40℃, at relative humidity ≦80%